Network element controller NEC(H) with
Q2 (HMS) protocol to supervise the distribution
path modules
Network element controller NECU(H)
with Q2 (HMS) protocol to supervise the return
path
modules
Communication of the controllers with
the modules with a powerful serial bus (LON
bus)
Supervision
and configuration of modules, administration
of modules and storage of configuration data
Communication of network element
controller NECH, NECUH and the HEC via RS485
and
HMS protocol
Possibility to connect
a LMT (local management terminal) to the
NECH, NECUH
respectively
an ECT (equipment craft terminal)
to the NEC,
NECU for local system diagnosis
Technical
Data
F
Interface
EIA RS232
Plug
connector type
9-pin
Sub-D
Electrical
Q2 Interface
EIA
RS485
Plug
connector type
15-pin
Sub-D
Power
consumption
≤ 8.4
W (NECH)
≤
4.0 W (NECUH)
Dimensions
NECH:
BK equipment practice
Module
width 1
NECUH:
S9 equipment practice
210
mm x 21 mm x 233 mm
Weight
NECH
~1.3
kg
NECUH
~1.0
kg
BKtel systems GmbH & Co. KG - www.bktel.com - E-Mail: info@bktel.com Specifications subject to change