  0Fx-ES26XL
0External modulated Optical CATV and
0SAT-IF Transmitter 1550 nm
  0 print pdf version  
  Fx-DS26XL  
 

Application

  • Electrical to optical conversion of multi-channel CATV signals like AM-VSB, FM and QAM signals
  • Electrical to optical conversion of SAT-IF video signals by separate input
  • Downstream transmission in HFC and RF Overlay networks with excellent performance
  • Externally modulated 1550 nm DFB laser transmitter
  • Enables the usage of optical amplifiers (EDFAs) as boosters or repeaters in order to realize large scale HFC networks

Features

  • 2 optical outputs with > 10 dBm optical output power each
  • Low noise, narrow linewidth CW DFB laser with DWDM wavelength according to ITU grid
    and adjustable wavelength
  • Bandwidth of 47…870 MHz for CATV and 950…2605 MHz for SAT-IF input
  • Separate RF input for SAT-IF signals
  • Automatic load control (ALC) for CATV signal input, separate ALC for SAT-IF signal input
  • Adjustable RF slope
  • Front panel CATV- and separate SAT-IF test point
  • Dual, hot-pluggable power supply modules for 100...240 VAC and ±48 VDC
  • Web and SNMP Interface (a-version)
  • LC display and LED status indication
  • General purpose I/O interface for remote functions
  • Very thin, only 1 U design for mounting into 19”, ETSI or JIS racks


 
  Block Diagram  
     
  Fx-ES26XL  
     
 
Technical Data
 
General
Unit
Optical Connector
Any type of high return loss connectors front or rear side mounted
Optical fiber
standard single mode 9/125 µm
RF-connector
F-female, front or rear side mounted
Control interface
a-version: Ethernet 10/100 interface:,
b-version: RS485/232 interface
Power supply types
(Dual redundant, hot pluggable)
100...240 VAC, 50/60 Hz
+/- 36...+/- 72 VDC

(Real) Power consumption
[W]
< 60 / 68 (1/2 power supply unit(s) equipped
Enlosure
19” / 1 rack unit [U]
(optionally compatible to ETSI or JIS standards)
Weight
[kg]

~ 9.0 (depend on power supply)

Safety
EN 60950, Laser class 1M according IEC 60 825-1 (eyesafe for normal viewing)
EMC
EN50083-2
Climatic specification
  Operation
  Storage

ETS 300 019, class 3.1
ETS 300 019, class 1.2
Optical Properties
Unit
Fx-ES26XL-85
FX-ES26XL-100
Wavelength
[nm]
1548 … 1560 nm or ITU-grid (CH23… CH37)
Side mode suppression
[dB]
>30
Wavelength adjustment range
[GHz]
-100, -50, 0, 50, 100
Optical power
[dBm]
2 x 8.5 min.
2 x 10.0 min,
Relative intensity noise
(opt. return loss > 40 dB)
[dBc/Hz]
<-158
typ. <–160
Maximum SBS suppression threshold
 CATV & SAT-IF application,
  25 km
 CATV application, 65 km



[dBm]
[dBm]



+15 *)
+19
Laser linewidth (typ.)
[MHz]
0.3
*) SBS suppression threshold should be adjusted application individually as low as possible for best signal
    performance, since using +14…+15 dBm threshold may result in 2 dB penatly of CNR for carrier
    frequencies 80…110 MHz and 4 dB penalty for band I (47…68 MHz) carrier frequencies.

 
     
 
Electrical PropertiesCATV

Unit
     
RF frequency range
[MHz]
47 ... 862
Frequency response flatness
[dB]
< +/- 0.75
Nom. Input level per TV channel
[dBµV]
80
Input level range (per carrier)
[dBµV]
78...96 (for OMI = 5% per CATV carrier)
True RMS input level range
[dBm]
-16...+2 (for ALC correctly working)
Slope range
[dB]
-2 (cable equivalent) ... +8 (cable equalization)
RF impedance
[Ω]

75

Return loss
[dB]
> 20 (@ 47 MHz) - 1.5 dB/octave, minimum 15
RF monitor (test point) level
[dB]
-20 ( -0.8...+0.2)
 
     
 
Electrical PropertiesSAT-IF

Unit
     
RF frequency range
[MHz]
950...2605
Frequency response flatness
[dB]
< +/- 2
Input level range (per SAT-IF carrier)
[dBµV]
82...98 (for OMISAT = 1.0%)
True RMS input level range
[dBm]
-11...+5 (for ALC correctly working)
RF impedance
[Ω]

75

Return loss
[dB]
>10
RF monitor (test point) level
[dBµV]
66 +/- 2.5 (for OMI = 1.0%)
 
     
       Performance Characteristics CATV  
 
Transmitter version
Unit
C42
D84
N77
Channel allocation plan for test
CENELEC 42
PAL-D 84
NTSC 77
number of TV carriers
 
42
84
77
Noise bandwidth
[MHz]
5
5
4
CNR Tx/Rx *)
[dB]
54.5 (52.5)
51.5 (49.5)
53 (51)
CNR Link 1*)
[dB]
53.5 (51.5)
50.5 (48.5)
52 (50)
CSO Tx/Rx and Link 1**)
[dBc]
64
CTB Tx/Rx and Link 1
[dBc]
63
*)  Values are valid for pure CATV application, value in backets (…) are valid for CATV & SAT-IF
    application with 36 QPSK modulated SAT-IF signals with carrier frequencies in the range of
    1000 … 2600 MHz
**) Optical output #1
 
     
       Performance Characteristics SAT-IF  
 
 
Unit
     
CNR *)
[dB]
> 27
Intermoduation products
[dBc]
< -35 (including intermodulation due to CATV signal!)
Spurious signals *)
[dBc]
< -38
*)  Measurement conditions as described in table “Test Condition” under row “Tx/Rx”; moreover
    36 QPSK modulated SAT-IF signals with carrier frequencies in the range of 1000 … 2600 MHz and
    27 MHz IF bandwidth are used.
 
     
 
Test Conditions
Booster EDFA 2)
1st Fiber Length 3)
In-Line EDFA 2)
2nd Fiber Length 3)
Receiver
Popt,Tx 4)
Tx/Rx 1)
no
no
no
no
0 dBm
Link 1 1)
15 dBm
25 km
no
no
0 dBm
Transmitter mode for all tests
ALC of both, CATV and SAT-IF input switched ON!
 
     
       1) RF input level at 80 dBμV per TV carrier
     2) EDFA with noise figure N= 5 dB
     3) Non-dispersion shifted fiber
     4) Receiver Rx with equivalent input noise current density of IEQ= 7 pA/
ÖHz and efficiency η = 0.95 A/W
 
     
 
Ordering information
 
For more information on this product please contact BKtel communications. Properties for ordering optical transmitter Fx-ES26XL
Optical output power

85
100

+8.5 dBm
+10.0 dBm
Freyuency plan *)
C42
N77
PAL84
Cenelec 42
NTSC 77
PAL 84
NMS-Interface
A
B
HTTP/SNMP Ethernet
RS485
Wavelength
X
15xx.xx
1548...1560
15xx.xx ITU wavelength
Optical connector
1
2
3
4
5
E2000
SC/APC
FC/APC-NTT
FC/APC_JDS
SC/APC with shutter
RF input / optical output
F
R
on front side
on rear side
Version
0
OEM

BKtel
OEM

Power supply

230/230
48/48
230
48
230/48

2 x (100...240 VAC)
2 x (36...72 VDC)
1 x (100...240 VDC)
1x (36...72 VDC)
mixed 230 VAC / 48 VDC
Power Plug
0
Eu
US
Sw
UK
Jp
Ch
No power cable included
Europe (Germany, Spain ...)
USA
Switzerland
UK, Ireland
Japan
China
*) Other frequency plan on request!

 
 
 
Available ITU grid wavelengths
ITU Grid Ch. No.
DWDM Wavelength
 
ITU Grid Ch. No.
DWDM Wavelength
23
1558.98 nm
  31
1552.52 nm
24
1558.17 nm
 
32
1551.72 nm
25
1557.36 nm
 
33
1550.92 nm
26
1556.55 nm
 
34
1550.12 nm
27
1555.75 nm
 
35
1549.32 nm
28
1554.94 nm
 
36
1548.51 nm
29
1554.13 nm
 
37
1547.72 nm
30
1553.33 nm
     
Other wavelengths on request!      
 